| Parameter | Specification |
|---|---|
| Operation Environment | |
| Power requirements | AC100-240V (AC), 50/60Hz |
| Power | 70VA |
| Temperature | 0-40°C |
| Humidity | 15-95% non-condensing |
| Patient Range | Adults, Pediatric, Neonate |
| Display & Indicators | |
| Display | 12.1″ color TFT, 800×480 resolution, selectable multi-display: Standard, Large-font, Trend coexist, OxyCRG dynamic view |
| Indicators | Alarm light, Power light, Battery light, QRS beep and sound |
| Interface & Battery | |
| Interface | AC Power input socket, Network interface |
| Battery | Rechargeable li-ion Battery, 12hr max charging, 2hr continuous use |
| Alarm & Recording | |
| Trend Time | 1–96 hours |
| Alarm | User-adjustable High/Low limits with 3-level audible/visual alert |
| Networking | Connected to central monitoring system |
| Recorder (optional) | Built-in thermal array, 50mm paper width, 25mm/s print speed |
| ECG | |
| Lead Type | 5-lead and 3-lead selectable |
| Lead Selection | 5-lead: I, II, III, aVR, aVL, aVF, V | 3-lead: I, II, III |
| ECG Waveform | Up to 7-lead ECG |
| Gain Selection | x0.25, x0.5, x1, x2, Auto |
| Sweep Speed | 12.5mm/s, 25mm/s, 50mm/s |
| Heart Rate Range | Adult: 15-300bpm; Neonate/Pediatric: 15-350bpm |
| Accuracy | ±1% or ±1bpm |
| Resolution | ±1bpm |
| Filter | Diagnostic: 0.05-100Hz; Monitoring: 0.05-40Hz; Surgical: 1-20Hz |
| Protection | Withstand 4000VAC/50Hz isolation |
| Scaling Signal | 1mV ±5% |
| NIBP | |
| Method | Automatic oscillometric |
| Operation Modes | Manual / Automatic / Continuous |
| Auto Measure Time | Adjustable |
| Measurement Unit | mmHg / kPa selectable |
| Measurement Types | Systolic, Diastolic, Mean |
| Range of Systolic Pressure | Adult: 40–270 mmHg; Pediatric: 40–200 mmHg; Neonate: 40–135 mmHg |
| Range of Diastolic Pressure | Adult: 10–210 mmHg; Pediatric: 10–150 mmHg; Neonate: 20–100 mmHg |
| Range of Mean Pressure | Adult: 10–230 mmHg; Pediatric: 20–165 mmHg; Neonate: 20–110 mmHg |
| Accuracy | ±5mmHg (mean error), SD <8mmHg, double safety protection |
| Resolution | 1 mmHg |
| Alarm | Systolic, Diastolic, Mean |
| PR from NIBP | 40–300 bpm, ±3bpm or ±3% |
| SpOâ‚‚ | |
| Measurement Range | 0–100% |
| Resolution | 1% |
| Accuracy | ±2% (70–100%, Adult/Pediatric, no motion); ±3% (70–100%, Neonate, no motion) |
| Alarm Range | 1–100% |
| Pulse Rate | 20–300 bpm, Resolution: 1 bpm |
| Temperature | |
| Measurement Range | 0–50°C (32–122°F) |
| Resolution | 0.1°C |
| Accuracy | ±0.1°C (excluding sensor) |
| Channel | Dual-channel (optional) |
| Respiration | |
| Method | Thoracic impedance |
| Measurement Range | Adult: 0–120 BrPM; Neonate/Pediatric: 0–150 BrPM |
| Apnea Alarm | Yes |
| Alarm | Audible and visual |
| Other | |
| Alarm Range (ECG) | 15–350 bpm |
| S-T Segment Detection | Measurement range: -2.0mV to 2.0mV, Alarm range: -2.0mV to 2.0mV |