Parameter | Specification |
---|---|
Operation Environment | |
Power requirements | AC100-240V (AC), 50/60Hz |
Power | 70VA |
Temperature | 0-40°C |
Humidity | 15-95% non-condensing |
Patient Range | Adults, Pediatric, Neonate |
Display & Indicators | |
Display | 12.1″ color TFT, 800×480 resolution, selectable multi-display: Standard, Large-font, Trend coexist, OxyCRG dynamic view |
Indicators | Alarm light, Power light, Battery light, QRS beep and sound |
Interface & Battery | |
Interface | AC Power input socket, Network interface |
Battery | Rechargeable li-ion Battery, 12hr max charging, 2hr continuous use |
Alarm & Recording | |
Trend Time | 1–96 hours |
Alarm | User-adjustable High/Low limits with 3-level audible/visual alert |
Networking | Connected to central monitoring system |
Recorder (optional) | Built-in thermal array, 50mm paper width, 25mm/s print speed |
ECG | |
Lead Type | 5-lead and 3-lead selectable |
Lead Selection | 5-lead: I, II, III, aVR, aVL, aVF, V | 3-lead: I, II, III |
ECG Waveform | Up to 7-lead ECG |
Gain Selection | x0.25, x0.5, x1, x2, Auto |
Sweep Speed | 12.5mm/s, 25mm/s, 50mm/s |
Heart Rate Range | Adult: 15-300bpm; Neonate/Pediatric: 15-350bpm |
Accuracy | ±1% or ±1bpm |
Resolution | ±1bpm |
Filter | Diagnostic: 0.05-100Hz; Monitoring: 0.05-40Hz; Surgical: 1-20Hz |
Protection | Withstand 4000VAC/50Hz isolation |
Scaling Signal | 1mV ±5% |
NIBP | |
Method | Automatic oscillometric |
Operation Modes | Manual / Automatic / Continuous |
Auto Measure Time | Adjustable |
Measurement Unit | mmHg / kPa selectable |
Measurement Types | Systolic, Diastolic, Mean |
Range of Systolic Pressure | Adult: 40–270 mmHg; Pediatric: 40–200 mmHg; Neonate: 40–135 mmHg |
Range of Diastolic Pressure | Adult: 10–210 mmHg; Pediatric: 10–150 mmHg; Neonate: 20–100 mmHg |
Range of Mean Pressure | Adult: 10–230 mmHg; Pediatric: 20–165 mmHg; Neonate: 20–110 mmHg |
Accuracy | ±5mmHg (mean error), SD <8mmHg, double safety protection |
Resolution | 1 mmHg |
Alarm | Systolic, Diastolic, Mean |
PR from NIBP | 40–300 bpm, ±3bpm or ±3% |
SpOâ‚‚ | |
Measurement Range | 0–100% |
Resolution | 1% |
Accuracy | ±2% (70–100%, Adult/Pediatric, no motion); ±3% (70–100%, Neonate, no motion) |
Alarm Range | 1–100% |
Pulse Rate | 20–300 bpm, Resolution: 1 bpm |
Temperature | |
Measurement Range | 0–50°C (32–122°F) |
Resolution | 0.1°C |
Accuracy | ±0.1°C (excluding sensor) |
Channel | Dual-channel (optional) |
Respiration | |
Method | Thoracic impedance |
Measurement Range | Adult: 0–120 BrPM; Neonate/Pediatric: 0–150 BrPM |
Apnea Alarm | Yes |
Alarm | Audible and visual |
Other | |
Alarm Range (ECG) | 15–350 bpm |
S-T Segment Detection | Measurement range: -2.0mV to 2.0mV, Alarm range: -2.0mV to 2.0mV |