Patient Monitor

Technical Specifications General

 

ParameterSpecification
Operation Environment
Power requirementsAC100-240V (AC), 50/60Hz
Power70VA
Temperature0-40°C
Humidity15-95% non-condensing
Patient RangeAdults, Pediatric, Neonate
Display & Indicators
Display12.1″ color TFT, 800×480 resolution, selectable multi-display: Standard, Large-font, Trend coexist, OxyCRG dynamic view
IndicatorsAlarm light, Power light, Battery light, QRS beep and sound
Interface & Battery
InterfaceAC Power input socket, Network interface
BatteryRechargeable li-ion Battery, 12hr max charging, 2hr continuous use
Alarm & Recording
Trend Time1–96 hours
AlarmUser-adjustable High/Low limits with 3-level audible/visual alert
NetworkingConnected to central monitoring system
Recorder (optional)Built-in thermal array, 50mm paper width, 25mm/s print speed
ECG
Lead Type5-lead and 3-lead selectable
Lead Selection5-lead: I, II, III, aVR, aVL, aVF, V | 3-lead: I, II, III
ECG WaveformUp to 7-lead ECG
Gain Selectionx0.25, x0.5, x1, x2, Auto
Sweep Speed12.5mm/s, 25mm/s, 50mm/s
Heart Rate RangeAdult: 15-300bpm; Neonate/Pediatric: 15-350bpm
Accuracy±1% or ±1bpm
Resolution±1bpm
FilterDiagnostic: 0.05-100Hz; Monitoring: 0.05-40Hz; Surgical: 1-20Hz
ProtectionWithstand 4000VAC/50Hz isolation
Scaling Signal1mV ±5%
NIBP
MethodAutomatic oscillometric
Operation ModesManual / Automatic / Continuous
Auto Measure TimeAdjustable
Measurement UnitmmHg / kPa selectable
Measurement TypesSystolic, Diastolic, Mean
Range of Systolic PressureAdult: 40–270 mmHg; Pediatric: 40–200 mmHg; Neonate: 40–135 mmHg
Range of Diastolic PressureAdult: 10–210 mmHg; Pediatric: 10–150 mmHg; Neonate: 20–100 mmHg
Range of Mean PressureAdult: 10–230 mmHg; Pediatric: 20–165 mmHg; Neonate: 20–110 mmHg
Accuracy±5mmHg (mean error), SD <8mmHg, double safety protection
Resolution1 mmHg
AlarmSystolic, Diastolic, Mean
PR from NIBP40–300 bpm, ±3bpm or ±3%
SpOâ‚‚
Measurement Range0–100%
Resolution1%
Accuracy±2% (70–100%, Adult/Pediatric, no motion); ±3% (70–100%, Neonate, no motion)
Alarm Range1–100%
Pulse Rate20–300 bpm, Resolution: 1 bpm
Temperature
Measurement Range0–50°C (32–122°F)
Resolution0.1°C
Accuracy±0.1°C (excluding sensor)
ChannelDual-channel (optional)
Respiration
MethodThoracic impedance
Measurement RangeAdult: 0–120 BrPM; Neonate/Pediatric: 0–150 BrPM
Apnea AlarmYes
AlarmAudible and visual
Other
Alarm Range (ECG)15–350 bpm
S-T Segment DetectionMeasurement range: -2.0mV to 2.0mV, Alarm range: -2.0mV to 2.0mV

Enquire Form

Want to know more about the product ? Just fill out the form below!

Enquire Now

Download Brochure for Patient Monitor

Patient Monitor

Download Brochure for 12 Channel ECG Holter

12 Channel ECG Holter

Download Brochure for Aspire Advance Fetal Care

Aspire Advance Fetal Care

Download Brochure for 3 Channel ECG Holter

3 Channel ECG Holter

Download Brochure for Aspire BPH-01 NIBP Holter

Aspire BPH-01 NIBP Holter

Download Brochure for Aspire 12 CH ECG Machine

Aspire 12 CH ECG Machine